1. उत्पादन समाप्तview
The Hilti CP 606 Firestop Sealant is a high-performance, intumescent acrylic sealant designed for firestopping applications. It expands when exposed to heat, forming a fire-resistant barrier that helps prevent the spread of fire and smoke through penetrations in fire-rated constructions. This product is suitable for various joint and penetration sealing applications in walls and floors.

An image showing a single 10.5oz tube of Hilti CP 606 red firestop sealant, clearly displaying the Hilti logo and product identification.
2. सुरक्षा जानकारी
Always prioritize safety when working with sealants. Read and understand the Safety Data Sheet (SDS) before use. Observe all local safety regulations.
- व्यक्तिगत सुरक्षा उपकरण (पीपीई): छाला र आँखाको सम्पर्कबाट बच्नको लागि सुरक्षा चश्मा, पन्जा र सुरक्षात्मक कपडा सहित उपयुक्त PPE लगाउनुहोस्।
- भेन्टिलेसन: Use in well-ventilated areas. If adequate ventilation is not available, use respiratory protection.
- छाला सम्पर्क: छालाको सम्पर्कको अवस्थामा, साबुन र पानीले राम्ररी धुनुहोस्।
- आँखा सम्पर्क: In case of eye contact, flush immediately with plenty of water for several minutes and seek medical attention.
- इन्जेसन: निल्नुभएमा, तुरुन्तै चिकित्सकीय ध्यान खोज्नुहोस्।
- पहुँच बाहिर राख्नुहोस्: बच्चाहरू र घरपालुवा जनावरहरूको पहुँचबाट टाढा राख्नुहोस्।
१. सेटअप र तयारी
- सतह तयारी: Ensure all surfaces to be sealed are clean, dry, and free from dust, oil, grease, loose particles, and other contaminants. Substrates should be sound and stable.
- Joint Dimensions: Verify that joint dimensions are within the product's specified limits for optimal performance.
- ब्याकिङ सामाग्री: For deeper joints, use a suitable backing material (e.g., backer rod) to control sealant depth and ensure proper sealant geometry.
- आवश्यक उपकरणहरू:
- Standard caulking gun
- Utility knife or sealant cutter
- Trowel or tooling stick for finishing
- Cleaning supplies (rags, appropriate solvent if needed)
- तापक्रम: Apply the sealant within the recommended temperature range, typically between 5°C and 40°C (41°F and 104°F).
4. आवेदन निर्देशनहरू
- कार्ट्रिज तयार गर्नुहोस्: Cut the tip of the sealant tube at a 45-degree angle to the desired bead size. Puncture the inner seal of the cartridge.
- कल्किंग गन लोड गर्नुहोस्: Insert the prepared cartridge into a standard caulking gun.
- सीलेन्ट लागू गर्नुहोस्: Apply the sealant evenly and continuously into the joint or penetration, ensuring full contact with the substrate. Maintain consistent pressure on the trigger to achieve a smooth, uniform bead.
- टुलिङ: Within 5-10 minutes of application (before skinning occurs), tool the sealant to ensure good adhesion and a smooth finish. Remove any excess sealant immediately.
- निको पार्ने: The sealant will skin over in approximately 15-30 minutes, depending on temperature and humidity. Full cure time can range from several days to weeks, depending on bead thickness and environmental conditions. Protect the freshly applied sealant from water and heavy traffic until fully cured.
5. मर्मतसम्भार
Once cured, Hilti CP 606 Firestop Sealant requires minimal maintenance. Periodically inspect sealed joints and penetrations for any signs of damage, cracking, or degradation. If damage is observed, clean the area and reapply sealant as necessary to maintain the firestop integrity.
T. समस्या निवारण
- कमजोर आसंजन:
Ensure surfaces are clean, dry, and free of contaminants. Proper surface preparation is critical for good adhesion.
- ढिलो उपचार:
Low temperatures and high humidity can extend curing times. Ensure adequate ventilation and maintain recommended application temperatures.
- Cracking or Shrinkage:
Excessive joint movement or improper joint design can lead to cracking. Ensure correct joint dimensions and use of backing material where appropriate.
7. निर्दिष्टीकरणहरू
| सुविधा | विवरण |
|---|---|
| ब्रान्ड | HILTI |
| मोडेल नम्बर | 3436798 (CP 606) |
| वस्तु फारम | Liquid (Sealant) |
| रङ | रातो |
| कन्टेनर आकार | 10.5 oz Tube |
| पानी प्रतिरोध स्तर | वाटरप्रूफ |
| निर्माता | हिल्टी |
| पहिलो उपलब्ध मिति | अक्टोबर 9, 2017 |
8. भण्डारण र निपटान
- भण्डारण: Store the sealant in its original, unopened packaging in a cool, dry place, away from direct sunlight and extreme temperatures. Recommended storage temperature is typically between 5°C and 25°C (41°F and 77°F).
- निपटान: Dispose of unused product and empty containers in accordance with local, state, and federal regulations. Do not dispose of in drains or waterways. Consult local waste management authorities for proper disposal methods.
9. वारेन्टी र समर्थन
For specific warranty information regarding the Hilti CP 606 Firestop Sealant, please refer to the official Hilti website or contact Hilti customer service directly. Hilti provides comprehensive technical support and product documentation to assist with proper application and performance.
हिल्टी आधिकारिक Webसाइट: www.hilti.com